Horizontal woltmann removable element dry type cold(hot) water meter

bulk removable element dry type cold(hot) water meter

Model:LXLC-50~500;LXLC/R-50-500                                                                               Illustration

Application:
Measuring the volume of cold or hot water passing through the pipeline

Quality:
·Magnet-drive, dry dial, register sealed in vacuum, resistance to magnet and fog-proof, forever clean and legible dial for reading.
·High quality material applied to guarantee its function efficient and reliable.
·Low head loss
·Removable mechanism is easy to replace or fix and not required detaching the body from the pipeline.
·Pulse emitter can be installed to this type for remote reading.

Working condition:
temperature:
≤40℃ for cold potable water meter
≤90℃ for hot water meter
Pressure:≤11Mpa

Maximum Permissible Error:
Qmin→Qt(ex Qt)=±5%;
Qt→Qs(both included)=±2% or ±3%(hot water)
Qmin=Min Flow, Qt=Transition Flow, Qs= Max Flow.

Main Technical Data
Meter Size (mm) class Max Flow Nominal Flow Transition Flow Min Flow Min Reading lectura Max Reading lectura
m3/h m3/h m3
50 B 30 15 3 0.45 0.01 999999
65 B 50 25 5 0.75 0.01 999999
80 B 80 40 8 1.2 0.01 999999
100 B 120 60 12 1.8 0.01 999999
125 B 200 100 20 3 0.01 999999
150 B 300 150 30 4.5 0.01 999999
200 B 500 250 50 7.5 0.01 999999
250 B 800 400 80 12 0.01 9999999
300 B 1200 600 120 18 0.01 9999999
400 B 2000 1000 200 30 0.01 9999999
500 B 3000 1500 300 45 0.01 9999999
Dimensions and weight
Meter Size
Length Width Height Connecting Thread Weight KG
D D1 Connecting Bolt
mm kg
50 200 175 257 165 125 4ŚM16 12
65 200 185 267 185 145 4ŚM16 13
80 225 200 277 200 160 8ŚM16 15
100 250 220 287 220 180 8ŚM16 19
125 250 245 297 245 210 8ŚM16 22
150 250 285 375 285 240 8ŚM20 47
200 350 345 400 340 295 8ŚM20 48
250 450 395 484 395 350 8ŚM20 110
300 450 445 506 445 400 12ŚM20 115
400 500 565 621 565 515 16ŚM24 180
500 500 670 725 670 620 20ŚM24 330

Horizontal woltmann removable element pulse transmitting water meter

bulk removable element pulse transmitting water meter

Model:LXLCY-50~500;LXLCY/R-50~500

APPLICATION AND FEATURES
Measuring the volume of cold or hot water passing through the pipeline

Quality:
Data refer to LXLC-50-500 water meter
Water meter equipped with a Reed Switch Pulser which can be connected to remote reading systems. The Reed Switch Pulser sends out electric signals per a preset water quantity.
Comes in several model variation, which indicate different pulse rates. To choose the variation best suited to your needs as per below diagram.

REED-SWITCH ELECTRIC DATA
Switch voltage: 24VAC/ DC
Switch current: 0.01A max

Working condition:
temperature:
≤40℃;for cold potable water meter
≤90℃ for hot water meter
Pressure:≤ 11Mpa

Maximum Permissible Error:
In the lower zone from Qmin inclusive up to but excluding Qt is: Cold potable
In the upper zone from Qt inclusive up to and including Qs is: Cold potable
water meter±2% Hot water meter±3%

OUTPUT DAT
Size  
100L/Pulse 1000L/Pulse 10000L/Pulse
50mm v v v
65mm v v v
80mm v v v
100mm v v v
125mm v v v
150mm   v v
200mm   v v
250mm     v
300mm     v
400mm     v
500mm     v