Horizontal woltmann removable element pulse transmitting water meter

Remote Reading Bulk Water Meter

Model:LXLCY-50~500

APPLICATION
Measuring the volume of cold potable water passing through the pipeline

Quality:
Data refer to LXLC-50-500 water meter
Water meter equipped with a Reed Switch Pulser which can be connected to remote reading systems. The Reed Switch Pulser sends out electric signals per a preset water quantity.
Comes in several model variation, which indicate different pulse rates. To choose the variation best suited to your needs as per below diagram.

REED-SWITCH ELECTRIC DATA
Switch voltage: 24VAC/ DC
Switch current: 0.01A max

Working condition:
temperature:
≤40℃for cold potable water meter
≤90℃for hot water meter
Pressure: =1Mpa

Maximum Permissible Error
Qmin→Qt(ex Qt)=±5%;
Qt→Qs(both included)=±2% or ±3%(hot water)
Qmin=Min Flow, Qt=Transition Flow, Qs= Max Flow.

OUTPUT DAT
Size  
100L/Pulse 1000L/Pulse 10000L/Pulse
50mm v v v
65mm v v v
80mm v v v
100mm v v v
125mm v v v
150mm   v v
200mm   v v
250mm     v
300mm     v
400mm     v
500mm     v
Main Technical Data
Meter Size (mm) class Max Flow Nominal Flow Transition Flow Min Flow Min Reading lectura Max Reading lectura
m3/h L/h m3
50 B 30 15 3 0.45 0.01 999999
65 B 50 25 5 0.75 0.01 999999
80 B 80 40 8 1.2 0.01 999999
100 B 120 60 12 1.8 0.01 999999
125 B 200 100 20 3 0.01 999999
150 B 300 150 30 4.5 0.01 999999
200 B 500 250 50 7.5 0.01 999999
250 B 800 400 80 12 0.01 999999
300 B 1200 600 120 18 0.01 999999
Dimensions and weight
Meter Size
Length Width Height Connecting Thread Weight KG
D D1 Connecting Bolt
mm kg
50 200 175 257 165 125 4ŚM16 12
65 200 185 267 185 145 4ŚM16 13
80 225 200 277 200 160 8ŚM16 15
100 250 220 287 220 180 8ŚM16 19
125 250 245 297 245 210 8ŚM16 22
150 250 285 375 285 240 8ŚM20 47
200 350 345 400 340 295 8ŚM20 48
250 450 395 484 395 350 8ŚM20 110
300 450 445 506 445 400 12ŚM20 115